+86-769-81580307
Availability: | |
---|---|
Quantity: | |
GC-DRS-A
GC
A. Product Introduction
GC-DRS-A single wire and cable vertical burning tester is suitable for measuring the vertical burning non-spreading performance of single plastic wire, control wire, cross-linked, elevator, ship, mining cable, etc. It can also be used for vertical burning test of high self-extinguishing low-smoke halogen-free flame-retardant olefin irradiated insulating material.
B. Test Standards
GB/T 18380.11-2008 Combustion test of cables and fiber optic cables in flame conditions Part XI
GB/T 18380.12-2008 Combustion test of cables and fiber optic cables in flame conditions Part XII
IEC60332-1-2:2004 Optical cable burning test
IEC60332-1-3:2004 Insulated wire dripping test
IEC60332-2-1:2004 Test of cables and optical cables under fire conditions
IEC60332-2-2:2004 Cable and optical cable test in fire environment
En50265-1 VDE low smoke halogen-free flame retardant test standard
GB/T5169.14-2007 Fire hazard test of electric and electronic products Part 14
IEC60695-11-2:2003 Fire Hazard Test - Part 12
C. Specifications
Model | GC-DRS-A |
Burning box | 30*120*45(W*H*D) |
Burning blowtorch | 1KW combustion nozzle, blue flame height is 50 to 60mm, the total height of the flame is 170 to 190mm |
Gas | Using high-purity 95% technical grade propane gas |
Sample length | 600±25mm |
Sample bracket | The distance between the lower edge of the upper bracket and the upper edge of the lower bracket of the two horizontal brackets is 550mm |
Fire time | 0.1-999.9s continuous setting |
Control function | Choose manually or automatically |
Gas flow range | 100-1000ml/min |
Air flow range | 1-10L/min |
Pressure gauge | 0~0.75kpa (adjustable) |
Ignition method | High-voltage automatic ignition |
Power |
D.Image display
F.Package & Delivery
Standard Export Wooden Package
Sea freight/Air transport/Express delivery